Anode Baskets,Bags & HooksAnode Baskets Titanium anode baskets or anode cages are available in a variety of shapes, sizes and materials. They are designed to hold the anodes, which provide a source of metallic ions to be plated, and carry the electric current that drives the electroplating process.PreciseHeater is dedicated to being the premiere supplier of corrosion resistant anode baskets to the Metal Finishing, Plating and Anodizing Industries.Anode baskets are built to the highest standards in the industry and are backed by a five-year warranty on workmanship. If st...
Release Time: 2021 - 04 - 01
Pulse Reverse power supplies, Cabinet modelsCooling: Water cooledOutput power: max. 64000 WattsEffective - and DC-current: max. 4240 APulse current: max. 9600 AEffective voltage: max. 6 VOutput power:  max. 2 x 16000 Watts (max. 4 x 8000 Watts)Effective - and DC-current:  max. 2 x 1060 A (max. 4 x 424 A)Reverse-current: max. 2 x 2400 A (max. 4 x 960 A)Effective voltage: Standard 2 x 6 V (4 x 6 V), other voltages on request (up to 600V)Typical applications:PCB lines Characteristic valuesSwitch mode technologyDual output, 4-fold output (single output optional) (see below matrix)Linearity inaccuracy Ripple less than Complex waveformsConstant current regulation (voltage regulation on request)SPI interface for control unit pe8005Fast rise and fall times (rectangular wav...
Release Time: 2021 - 03 - 16
PVDF/PFA/PTFE Heat ExchangersTeflon(Fluorpolymer) Heating and cooling coilsExchange areaSq.FtConnectionsInchLengthIn./mmWidthIn./mmThicknessIn./mmModel No.5.53/4 FNPT11.5(292)11.5(292)2(51)XC-12-12113/4 FNPT15.5(394)15.5(394)2(51)XC-16-1616.53/4 FNPT17.5(445)17.5(445)2.36(60)XC-18-18223/4 FNPT19.7(500)15.7(400)2.36(60)XC-20-1627.53/4 FNPT19.7(500)19.7(500)2.36(60)XC-20-20333/4 FNPT23.5(597)23.5(597)2.36(60)XC-24-2438.53/4 FNPT27.5(700)23.5(597)2.36(60)XC-28-24443/4 FNPT27.5(700)27.5(700)2.76(70)XC-28-2849.53/4 FNPT31.5(800)31.5(800)2.76(70)XC-32-32551 FNPT33.9(860)33.9(860)2.76(70)XC-34-3460.51 FNPT35.5(900)31.5(800)2.76(70)XC-36-32661 FNPT35.5(900)33.9(860)2.76(70)XC-36-3471.51 FNPT35.5(900)35.5(900)2.76(70)XC-36-36771 FNPT39.5(1000)33.9(860)3.15(80...
Release Time: 2016 - 07 - 27
Ruthenium Iridium Titanium AnodesBecause of a very flexible production facility, we are able to manufacture anodes of all types: sheet, plate, mesh, wire, rod, tubular or combinations and/or assemblies of these materials. Their size and number vary from several cm2 to 2 m2 and from 1 to 10,000 pieces. The process in which the anodes are used determines size, shape and coating specification of an anode.Important parameters determining the anode design are:◆ The electrochemical cell or installation wherein the anodes are used◆ The process conditions, such as electrolyte composition, temperature, current density, design life, etc.◆ Mechanical load of the anode◆ Capacity of electrical conductivity of the base material.All anodes are produced according to customer specifications. When these spe...
Release Time: 2016 - 07 - 21
Inline Fluoropolymer Chemical Heat Exchangers:Fluoropolymer Inline Heat ExchangersExchange Area(Sq.Ft)LengthIn(mm)DIAIn(mm)PP ShellPVDF Shell6.515.7(400)10(255)XCH6.5-***XPH6.5-***1315.7(400)12(305)XCH13-***XPH13-***2020(500)14(355)XCH20-***XPH20-***3020(500)14(355)XCH30-***XPH30-***4024(600)14(355)XCH40-***XPH40-***5024(600)16(405)XCH50-***XPH50-***6027.5(700)16(405)XCH60-***XPH60-***7027.5(700)16(405)XCH70-***XPH70-***8031.4(800)16(405)XCH80-***XPH80-***9031.4(800)18(460)XCH90-***XPH90-***10031.4(900)18(460)XCH100-***XPH100-***11031.4(900)20(510)XCH110-***XPH110-***12039(1000)20(510)XCH120-***XPH120-***13039(1000)20(510)XCH130-***XPH130-***14043(1100)22(560)XCH140-***XPH140-***15043(1100)22(560)XCH150-***XPH150-***16047(1200)22(560)XCH160-***XPH160-***  lnine chemical heat exch...
Release Time: 2016 - 07 - 21
Metal Heating and Cooling Grid CoilsDesigned for the high demands of corrosive chemical heatingor cooling DOUBLE C STYLE GRID COILS DCGExchange Area Squre Ft12-1/2” WIDTH Tubes Depth(In./mm)     Length(In./mm)    Model number6.582612.5/31814/35526DCG-148.82612.5/31818/45726DCG-18122612.5/31824/60926DCG-2415.62612.5/31830/76226DCG-30192612.5/31836/91426DCG-3625.82612.5/31848/1,21926DCG-48292612.5/31854/1,37126DCG-5434.92612.5/31864/1,62526DCG-6418-1/2” WIDTH Tubes  Depth(In./mm)   Length(In./mm)      Model number133818.5/47018/45738DCG-18183818.5/47024/60924DCG-24233818.5/47030/76224DCG-3027.93818.5/47036/91424DCG-36353818.5/47048/1,21924DCG-4842.93818.5/47054/1,37124DCG-54513818.5/47064/1,62524DCG-6459.53818.5/...
Release Time: 2016 - 07 - 21
SmartOne PTC Max Single Over the Side Heater :SmartOne heaters' elements are PTC positive temperature coefficient semiconductors – making the heaters self-limiting. That is, they reach a set maximum sheath temperature (which is below the ignition point of most combustible materials), meaning they are especially safe for process applications. WATTSVOLTSHot ZoneMM/IN.Overall MM/IN.304SS316SSTitaniumShip Wt.Lbs./(Kg)1000120240180(7)280(11)S1SP1111S1SP1211S1TP1111S1TP12117(3.5)2000240480330(13)430(17)S1SP2117S1SP2217S1TP2117S1TP221710(4.5)3000240480460(18)585(23)S1SP3223S1SP3423S1TP3223S1TP342311(5)4000240480610(24)735(29)S1SP4229S1SP4429S1TP4229S1TP442913(6)5000240480760(30)890(35)S1SP5235S1SP5435S1TP5235S1TP543515(7)6000240480890(35)1040(41)S1SP6241S1SP6441S1TP6241S1TP644117(8)...
Release Time: 2016 - 07 - 19
HX Style Spiral Over the side Teflon PTFE HEATERS:Specify thermal overload protection desired. Guards are recommended on over the side heaters and required on L-Shaped heaters. Standard guard is polypropylene. Fluoropolymer (PTFE) guards recommended for chromic acid and solutions exceeding 180º F (82ºC).GUARDS SOLD SEPARATELY WATTSVOLTSHot zonemm/inOverallmm/inMax coldzoneModel No.Ship WT.Lbs./Kg500120-240125(5)280(11)41(1040)HXP.5111HXP.5211   6  (2.5)1000120-240180(7)280(11)41(1040)HXP1111HXP1211   7  (3.5)2000120-240305(12)430(17)41(1040))HXP2117HXP2217HXP2417   8   (4)3000120-600405(16)585(23)41(1040)HXP3223HXP3423   13   (6)4000120-600510(20)735(29)41(1040)HXP42...
Release Time: 2016 - 07 - 13
3’’-5’’-6’’ Flange Heaters -Tubular Flanged Immersion HeatersTubular Heater Industrial Heating Heater: 3' 150 lbs. Stainless Steel Flange (3 Elements) Heater:WATTSVOLTSLengthMM./INModel NumberShip Wt.LBS./(Kg)3000240480230(9)3FLSP32093FLSP3409  14 (6.5)4500240480330(13)3FLSP4.52133FLSP4.5413  15  (7)6000240480485(19)3FLSP62193FLSP6419   16  (7.5)9000240480660(26)3FLSP92263FLSP9446  17  (8)12000240480840(33)3FLSP122333FLSP12433  18  (8.5)150002404801015(41)3FLSP152413FLSP15441 20 (9)180002404801245(49)3FLSP182493FLSP18449  21  (10)   5' 150 lbs. Stainless Steel Flange (6 Elements) Heater: WATTSVOLTSLengthMM./INModel NumberShi...
Products Product Details

Explosion-Proof Flanged Immersion Heaters

Spec:
Scope:
Availability: 2021 - 05 - 12
Describe:
Explain:
Explosion-Proof Flanged Immersion HeatersPreciseHeater’s explosion-proof flanged immersion heaters are one of the most widely used solutions for heating fluids and gases in hazardous locations.  CSA approved for Class 1, Division 1, Group B, C and D locations and/or approved for ATEX and IECEx Zone 1 and/or Zone 21 locations.  PreciseHeater's explosion-proof flange heaters are designed for use in tanks, vessels, and in-line heating.Product HighlightsWattages up to 8.5 megawattsWatt densities up to 200 w/in2Voltages up to 600VElement sheath temperatures up to 1,500°FMultiple flange and element materialsFlange sizes up to 30' and 2500# ASME B16.5Standard Construction FeaturesANSI B16.5 150# or 300# flange 3' up to 30' (max flange size of 24' for div 1 ...
  • Features


Explosion-Proof Flanged Immersion Heaters


Explosion-Proof Flanged Immersion Heaters


PreciseHeater’s explosion-proof flanged immersion heaters are one of the most widely used solutions for heating fluids and gases in hazardous locations.  CSA approved for Class 1, Division 1, Group B, C and D locations and/or approved for ATEX and IECEx Zone 1 and/or Zone 21 locations.  PreciseHeater's explosion-proof flange heaters are designed for use in tanks, vessels, and in-line heating.


Product Highlights

Wattages up to 8.5 megawatts

Watt densities up to 200 w/in2

Voltages up to 600V

Element sheath temperatures up to 1,500°F

Multiple flange and element materials

Flange sizes up to 30' and 2500# ASME B16.5


Standard Construction Features


ANSI B16.5 150# or 300# flange 3' up to 30' (max flange size of 24' for div 1 applications)

Designed to fit into schedule 40 or schedule STD pipe for the given flange size

Flange material A105 carbon stl, A182 304/304L or 316/316L stainless steel

Elements sheath materials available; steel, 304 SST, 316 SST, 321 SST, incoloy 800, incoloy 840, copper

Epoxy or RTV sealed heating elements to prevent moisture absorption

Stainless steel welded bussing to eliminate loose connections

Heater circuits divided into 48A max as default

Heavy duty, low pressure drop design, 304 SST element support spacers provided on 24' centers

Spacer support rods provided for immersed length greater than 30'

Lifting lugs for heaters 4' and larger

Nitrile bonded fiber, or SST/graphite spiral flange gasket provided as standard


Optional Features

Extended terminal box


Provided when necessary to allow for cooler operation of the terminal box. This allows the heating elements to be sealed with epoxy or RTV and for the customer to provide incoming wire with a much lower insulation temperature rating.


ASME
The heater can be supplied in accordance with ASME section VIII Div. 1 U-Part stamped and certified.


Thermostats

Bulb and capillary pilot duty or load carrying thermostats can be provided to control the heater. The thermostat bulb can be installed in a thermowell to sense process or element sheath temperature.


Thermocouples
Type J or K thermocouples can be provided to monitor the process or element sheath temperatures. Thermocouples provided with a ceramic wafer head and screw terminals for ease of wiring. Alternate type E or T available.


Hermetically sealed element terminations
A ceramic to metal soldered seal can be provided to eliminate the possibility of moisture from entering the heating element.


Removable bussing
Allows troubleshooting and isolation of a failed heating element.


Cross-baffle
Construction utilizes alternating half baffles spaced closely to cause increased flow velocity across the heating elements to allow better heat transfer from the elements to the fluid.


Add support rods for flanges with length less than 30'
Support rods can be added to shorter heater with high flow to keep the element support spacers in place.


Larger heater circuits for greater than 48A per circuit

Heavy wall pipe design
Element bundles with smaller outside diameter can be provided for any flange size requested.


Pickle and Passivate
A chemical treatment in nitric acid can be performed to remove free iron from the outer surface of stainless steel for applications sensitive to contaminants. 


Electro-polish
Is a process similar to plating using cathode and anode reactions but material is removed rather than added to the heater surfaces in order to provide a clean and bright finish.


Ring and cover weatherproof or corrosion resistant enclosures
Heavy duty pipe and plate construction.


Other element sheath and flange materials available

Flange ratings greater than 300# are available up to 2500#




Release Time: 2016 - 07 - 13
3’’-5’’-6’’ Flange Heaters -Tubular Flanged Immersion HeatersTubular Heater Industrial Heating Heater: 3' 150 lbs. Stainless Steel Flange (3 Elements) Heater:WATTSVOLTSLengthMM./INModel NumberShip Wt.LBS./(Kg)3000240480230(9)3FLSP32093FLSP3409  14 (6.5)4500240480330(13)3FLSP4.52133FLSP4.5413  15  (7)6000240480485(19)3FLSP62193FLSP6419   16  (7.5)9000240480660(26)3FLSP92263FLSP9446  17  (8)12000240480840(33)3FLSP122333FLSP12433  18  (8.5)150002404801015(41)3FLSP152413FLSP15441 20 (9)180002404801245(49)3FLSP182493FLSP18449  21  (10)   5' 150 lbs. Stainless Steel Flange (6 Elements) Heater: WATTSVOLTSLengthMM./INModel NumberShi...
Release Time: 2002 - 05 - 28
18' 6KW 48 watts per sq. inch Flange Heater18 inch, 6kw, 48 watt per square inch flange heater. Suitable for heating process water and mild solutions.Titanium/316SS/Incoloy sheath element (other sheath material available)Titanium/316SS/Incoloy thermowell150lb. flange (300lb. available)1 or 3 phase208-600 voltN1, N4 and N7 Terminal housing optionsFor heavily corrosive applications, please call. Other sheath material, such as titanium, inconnel, monel and etc., are available.Optional Flange Heater Configurations:T1, T2 and T3 ThermostatsProcess Thermocouples: J, K or 100 ohm RTDHi-Limit over temp thermocouple clamped to element sheath: J or K
Release Time: 2001 - 05 - 08
20' 7.5KW 48 watts per sq. inch Flange Heater20 inch, 7.5kw, 48 watt per square inch flange heater. Suitable for heating process water and mild solutions.Titanium/316SS/Incoloy sheath element (other sheath material available)Titanium/316SS/Incoloy thermowell150lb. flange (300lb. available)1 or 3 phase208 to 600 voltN1, N4 and N7 Terminal housing optionsFor heavily corrosive applications, please call. Other sheath material, such as titanium, inconnel, monel and etc., are available.Optional Flange Heater Configurations:T1, T2 and T3 ThermostatsProcess Thermocouples: J, K or 100 ohm RTDHi-Limit over temp thermocouple clamped to element sheath: J or K
Release Time: 2001 - 05 - 01
26' 9KW 48 watts per sq. inch Flange Heater26 inch, 9kw, 48 watt per square inch flange heater. Suitable for heating process water and mild solutions.Titanium/316SS/Incoloy sheath element (other sheath material available)Titanium/316SS/Incoloy thermowell150lb. flange (300lb. available)1 or 3 phase208 to 600 voltN1, N4 and N7 Terminal housing optionsFor heavily corrosive applications, please call. Other sheath material, such as titanium, inconnel, monel and etc., are available.Optional Flange Heater Configurations:T1, T2 and T3 ThermostatsProcess Thermocouples: J, K or 100 ohm RTDHi-Limit over temp thermocouple clamped to element sheath: J or K
Release Time: 1996 - 05 - 08
Flanged Immersion HeaterImmersion HeatersOur immersion heaters has long been recognised as the most versatile and widely used source of electric, commercial, industrial, scientific and domestic heat. Our immersion heaters are used for a number of applications which include fluids, including water, oils, chemicals and more.Our industrial immersion heaters are reliable, strong, adaptable and suitable for an unlimited number of applications and environments. Elmatic has the expertise, design and manufacturing facilities to meet your particular requirements, whether it’s a large quantity requirement or a special one.Depending on the application required, these immersion heaters can be made in various types of materials including incoloy, stainless steel, mild steel and titanium. Enabling tempe...
Release Time: 2021 - 05 - 10
41' 15KW 48 watts per sq. inch Flange Heater41 inch, 15kw, 48 watt per square inch flange heater. Suitable for heating process water and mild solutions.Titanium/316SS/Incoloy sheath element (other sheath material available)Titanium/316SS/Incoloy thermowell150lb. flange (300lb. available)1 or 3 phase208 to 600 voltN1, N4 and N7 Terminal housing optionsFor heavily corrosive applications, please call. Other sheath material, such as titanium, inconnel, monel and etc., are available.Optional Flange Heater Configurations:T1, T2 and T3 ThermostatsProcess Thermocouples: J, K or 100 ohm RTDHi-Limit over temp thermocouple clamped to element sheath: J or K
Release Time: 2001 - 05 - 09
33' 12KW 48 watts per sq. inch Flange Heater33 inch, 12KW, 48 watt per square inch flange heater. Suitable for heating process water and mild solutions.Titanium/316SS/Incoloy sheath element (other sheath material available)Titanium/316SS/Incoloy thermowell150lb. flange (300lb. available)1 or 3 phase208 to 600 voltN1, N4 and N7 Terminal housing optionsFor heavily corrosive applications, please call. Other sheath material, such as titanium, inconnel, monel and etc., are available.Optional Flange Heater Configurations:T1, T2 and T3 ThermostatsProcess Thermocouples: J, K or 100 ohm RTDHi-Limit over temp thermocouple clamped to element sheath: J or K
Release Time: 2001 - 05 - 23
48'' 18KW 48 watts per sq. inch Flange Heater48 inch, 18kw, 48 watt per square inch flange heater. Suitable for heating process water and mild solutions.Titanium/316SS/Incoloy sheath element (other sheath material available)Titanium/316SS/Incoloy thermowell150lb. flange (300lb. available)1 or 3 phase208 to 600 voltN1, N4 and N7 Terminal housing optionsFor heavily corrosive applications, please call. Other sheath material, such as titanium, inconnel, monel and etc., are available.Optional Flange Heater Configurations:T1, T2 and T3 ThermostatsProcess Thermocouples: J, K or 100 ohm RTDHi-Limit over temp thermocouple clamped to element sheath: J or K
Release Time: 2001 - 05 - 09
52' 20KW 48 watts per sq. inch Flange Heater52 inch, 20kw, 48 watt per square inch flange heater. Suitable for heating process water and mild solutions.Titanium/316SS/Incoloy sheath element (other sheath material available)Titanium/316SS/Incoloy thermowell150lb. flange (300lb. available)1 or 3 phase208 to 600 voltN1, N4 and N7 Terminal housing optionsFor heavily corrosive applications, please call. Other sheath material, such as titanium, inconnel, monel and etc., are available.Optional Flange Heater Configurations:T1, T2 and T3 ThermostatsProcess Thermocouples: J, K or 100 ohm RTDHi-Limit over temp thermocouple clamped to element sheath: J or K
Release Time: 1998 - 11 - 03
Explosion-Proof Flanged Immersion HeatersPreciseHeater’s explosion-proof flanged immersion heaters are one of the most widely used solutions for heating fluids and gases in hazardous locations.  CSA approved for Class 1, Division 1, Group B, C and D locations and/or approved for ATEX and IECEx Zone 1 and/or Zone 21 locations.  PreciseHeater's explosion-proof flange heaters are designed for use in tanks, vessels, and in-line heating.Product HighlightsWattages up to 8.5 megawattsWatt densities up to 200 w/in2Voltages up to 600VElement sheath temperatures up to 1,500°FMultiple flange and element materialsFlange sizes up to 30' and 2500# ASME B16.5Standard Construction FeaturesANSI B16.5 150# or 300# flange 3' up to 30' (max flange size of 24' for div 1 ...
Release Time: 1996 - 05 - 16
62' 25KW 48 watts per sq. inch Flange Heater62 inch, 25kw, 48 watt per square inch flange heater. Suitable for heating process water and mild solutions.Titanium/316SS/Incoloy sheath element (other sheath material available)Titanium/316SS/Incoloy thermowell150lb. flange (300lb. available)1 or 3 phase208 or 600 voltN1, N4 and N7 Terminal housing optionsFor heavily corrosive applications, please call. Other sheath material, such as titanium, inconnel, monel and etc., are available.Optional Flange Heater Configurations:T1, T2 and T3 ThermostatsProcess Thermocouples: J, K or 100 ohm RTDHi-Limit over temp thermocouple clamped to element sheath: J or K
Release Time: 2021 - 05 - 10
78' 30KW 48 watts per sq. inch Flange Heater78 inch, 30kw, 48 watt per square inch flange heater. Suitable for heating process water and mild solutions.Titanium/316SS/Incoloy sheath element (other sheath material available)Titanium/316SS/Incoloy thermowell150lb. flange (300lb. available)1 or 3 phase208 or 600 voltN1, N4 and N7 Terminal housing optionsFor heavily corrosive applications, please call. Other sheath material, such as titanium, inconnel, monel and etc., are available.Optional Flange Heater Configurations:T1, T2 and T3 ThermostatsProcess Thermocouples: J, K or 100 ohm RTDHi-Limit over temp thermocouple clamped to element sheath: J or K
Hot Products / Hot Products More
2021 - 05 - 12
Anode Baskets,Bags & HooksAnode Baskets Titanium anode baskets or anode cages are available in a variety of shapes, sizes and materials. They are designed to hold the anodes, which provide a source of metallic ions to be plate...
2021 - 04 - 01
Pulse Reverse power supplies, Cabinet modelsCooling: Water cooledOutput power: max. 64000 WattsEffective - and DC-current: max. 4240 APulse current: max. 9600 AEffective voltage: max. 6 VOutput power:  max. 2 x 16000 Watts (max. 4 x 8000 Watts)Effective - and DC-current:  max. 2 x 1060 A (max. 4 x 424 A)Reverse-current: max. 2 x 2400 A (max. 4 x 960 A)Effective voltage: Standar...
2021 - 03 - 16
PVDF/PFA/PTFE Heat ExchangersTeflon(Fluorpolymer) Heating and cooling coilsExchange areaSq.FtConnectionsInchLengthIn./mmWidthIn./mmThicknessIn./mmModel No.5.53/4 FNPT11.5(292)11.5(292)2(51)XC-12-12113/4 FNPT15.5(394)15.5(394)2(51)XC-16-1616.53/4 FNPT17.5(445)17.5(445)2.36(60)XC-18-18223/4 FNPT19.7(500)15.7(400)2.36(60)XC-20-1627.53/4 FNPT19.7(500)19.7(500)2.36(60)XC-20-20333/4&...
Service Hotline
020-31056110
客户端下载
Client Downloads
Copyright ©2005 - 2013 Guangzhou Precise Heater Co.,LTD
犀牛云提供企业云服务