Products Products
  / Products
Release Time: 2021 - 05 - 12
Anode Baskets,Bags & HooksAnode Baskets Titanium anode baskets or anode cages are available in a variety of shapes, sizes and materials. They are designed to hold the anodes, which provide a source of metallic ions to be plated, and carry the electric current that drives the electroplating process.PreciseHeater is dedicated to being the premiere supplier of corrosion resistant anode baskets to the Metal Finishing, Plating and Anodizing Industries.Anode baskets are built to the highest standards in the industry and are backed by a five-year warranty on workmanship. If st...
Release Time: 2021 - 04 - 01
Pulse Reverse power supplies, Cabinet modelsCooling: Water cooledOutput power: max. 64000 WattsEffective - and DC-current: max. 4240 APulse current: max. 9600 AEffective voltage: max. 6 VOutput power:  max. 2 x 16000 Watts (max. 4 x 8000 Watts)Effective - and DC-current:  max. 2 x 1060 A (max. 4 x 424 A)Reverse-current: max. 2 x 2400 A (max. 4 x 960 A)Effective voltage: Standard 2 x 6 V (4 x 6 V), other voltages on request (up to 600V)Typical applications:PCB lines Characteristic valuesSwitch mode technologyDual output, 4-fold output (single output optional) (see below matrix)Linearity inaccuracy Ripple less than Complex waveformsConstant current regulation (voltage regulation on request)SPI interface for control unit pe8005Fast rise and fall times (rectangular wav...
Release Time: 2021 - 03 - 16
PVDF/PFA/PTFE Heat ExchangersTeflon(Fluorpolymer) Heating and cooling coilsExchange areaSq.FtConnectionsInchLengthIn./mmWidthIn./mmThicknessIn./mmModel No.5.53/4 FNPT11.5(292)11.5(292)2(51)XC-12-12113/4 FNPT15.5(394)15.5(394)2(51)XC-16-1616.53/4 FNPT17.5(445)17.5(445)2.36(60)XC-18-18223/4 FNPT19.7(500)15.7(400)2.36(60)XC-20-1627.53/4 FNPT19.7(500)19.7(500)2.36(60)XC-20-20333/4 FNPT23.5(597)23.5(597)2.36(60)XC-24-2438.53/4 FNPT27.5(700)23.5(597)2.36(60)XC-28-24443/4 FNPT27.5(700)27.5(700)2.76(70)XC-28-2849.53/4 FNPT31.5(800)31.5(800)2.76(70)XC-32-32551 FNPT33.9(860)33.9(860)2.76(70)XC-34-3460.51 FNPT35.5(900)31.5(800)2.76(70)XC-36-32661 FNPT35.5(900)33.9(860)2.76(70)XC-36-3471.51 FNPT35.5(900)35.5(900)2.76(70)XC-36-36771 FNPT39.5(1000)33.9(860)3.15(80...
Release Time: 2016 - 07 - 27
Ruthenium Iridium Titanium AnodesBecause of a very flexible production facility, we are able to manufacture anodes of all types: sheet, plate, mesh, wire, rod, tubular or combinations and/or assemblies of these materials. Their size and number vary from several cm2 to 2 m2 and from 1 to 10,000 pieces. The process in which the anodes are used determines size, shape and coating specification of an anode.Important parameters determining the anode design are:◆ The electrochemical cell or installation wherein the anodes are used◆ The process conditions, such as electrolyte composition, temperature, current density, design life, etc.◆ Mechanical load of the anode◆ Capacity of electrical conductivity of the base material.All anodes are produced according to customer specifications. When these spe...
Release Time: 2016 - 07 - 21
Inline Fluoropolymer Chemical Heat Exchangers:Fluoropolymer Inline Heat ExchangersExchange Area(Sq.Ft)LengthIn(mm)DIAIn(mm)PP ShellPVDF Shell6.515.7(400)10(255)XCH6.5-***XPH6.5-***1315.7(400)12(305)XCH13-***XPH13-***2020(500)14(355)XCH20-***XPH20-***3020(500)14(355)XCH30-***XPH30-***4024(600)14(355)XCH40-***XPH40-***5024(600)16(405)XCH50-***XPH50-***6027.5(700)16(405)XCH60-***XPH60-***7027.5(700)16(405)XCH70-***XPH70-***8031.4(800)16(405)XCH80-***XPH80-***9031.4(800)18(460)XCH90-***XPH90-***10031.4(900)18(460)XCH100-***XPH100-***11031.4(900)20(510)XCH110-***XPH110-***12039(1000)20(510)XCH120-***XPH120-***13039(1000)20(510)XCH130-***XPH130-***14043(1100)22(560)XCH140-***XPH140-***15043(1100)22(560)XCH150-***XPH150-***16047(1200)22(560)XCH160-***XPH160-***  lnine chemical heat exch...
Release Time: 2016 - 07 - 21
Metal Heating and Cooling Grid CoilsDesigned for the high demands of corrosive chemical heatingor cooling DOUBLE C STYLE GRID COILS DCGExchange Area Squre Ft12-1/2” WIDTH Tubes Depth(In./mm)     Length(In./mm)    Model number6.582612.5/31814/35526DCG-148.82612.5/31818/45726DCG-18122612.5/31824/60926DCG-2415.62612.5/31830/76226DCG-30192612.5/31836/91426DCG-3625.82612.5/31848/1,21926DCG-48292612.5/31854/1,37126DCG-5434.92612.5/31864/1,62526DCG-6418-1/2” WIDTH Tubes  Depth(In./mm)   Length(In./mm)      Model number133818.5/47018/45738DCG-18183818.5/47024/60924DCG-24233818.5/47030/76224DCG-3027.93818.5/47036/91424DCG-36353818.5/47048/1,21924DCG-4842.93818.5/47054/1,37124DCG-54513818.5/47064/1,62524DCG-6459.53818.5/...
Release Time: 2016 - 07 - 21
SmartOne PTC Max Single Over the Side Heater :SmartOne heaters' elements are PTC positive temperature coefficient semiconductors – making the heaters self-limiting. That is, they reach a set maximum sheath temperature (which is below the ignition point of most combustible materials), meaning they are especially safe for process applications. WATTSVOLTSHot ZoneMM/IN.Overall MM/IN.304SS316SSTitaniumShip Wt.Lbs./(Kg)1000120240180(7)280(11)S1SP1111S1SP1211S1TP1111S1TP12117(3.5)2000240480330(13)430(17)S1SP2117S1SP2217S1TP2117S1TP221710(4.5)3000240480460(18)585(23)S1SP3223S1SP3423S1TP3223S1TP342311(5)4000240480610(24)735(29)S1SP4229S1SP4429S1TP4229S1TP442913(6)5000240480760(30)890(35)S1SP5235S1SP5435S1TP5235S1TP543515(7)6000240480890(35)1040(41)S1SP6241S1SP6441S1TP6241S1TP644117(8)...
Release Time: 2016 - 07 - 19
HX Style Spiral Over the side Teflon PTFE HEATERS:Specify thermal overload protection desired. Guards are recommended on over the side heaters and required on L-Shaped heaters. Standard guard is polypropylene. Fluoropolymer (PTFE) guards recommended for chromic acid and solutions exceeding 180º F (82ºC).GUARDS SOLD SEPARATELY WATTSVOLTSHot zonemm/inOverallmm/inMax coldzoneModel No.Ship WT.Lbs./Kg500120-240125(5)280(11)41(1040)HXP.5111HXP.5211   6  (2.5)1000120-240180(7)280(11)41(1040)HXP1111HXP1211   7  (3.5)2000120-240305(12)430(17)41(1040))HXP2117HXP2217HXP2417   8   (4)3000120-600405(16)585(23)41(1040)HXP3223HXP3423   13   (6)4000120-600510(20)735(29)41(1040)HXP42...
Release Time: 2016 - 07 - 13
3’’-5’’-6’’ Flange Heaters -Tubular Flanged Immersion HeatersTubular Heater Industrial Heating Heater: 3' 150 lbs. Stainless Steel Flange (3 Elements) Heater:WATTSVOLTSLengthMM./INModel NumberShip Wt.LBS./(Kg)3000240480230(9)3FLSP32093FLSP3409  14 (6.5)4500240480330(13)3FLSP4.52133FLSP4.5413  15  (7)6000240480485(19)3FLSP62193FLSP6419   16  (7.5)9000240480660(26)3FLSP92263FLSP9446  17  (8)12000240480840(33)3FLSP122333FLSP12433  18  (8.5)150002404801015(41)3FLSP152413FLSP15441 20 (9)180002404801245(49)3FLSP182493FLSP18449  21  (10)   5' 150 lbs. Stainless Steel Flange (6 Elements) Heater: WATTSVOLTSLengthMM./INModel NumberShi...
Products Product Details

Pulse Reverse power supplies, Cabinet models

Spec:
Scope:
Availability: 2021 - 05 - 12
Describe:
Explain:
Pulse Reverse power supplies, Cabinet modelsCooling: Water cooledOutput power: max. 64000 WattsEffective - and DC-current: max. 4240 APulse current: max. 9600 AEffective voltage: max. 6 VOutput power:  max. 2 x 16000 Watts (max. 4 x 8000 Watts)Effective - and DC-current:  max. 2 x 1060 A (max. 4 x 424 A)Reverse-current: max. 2 x 2400 A (max. 4 x 960 A)Effective voltage: Standard 2 x 6 V (4 x 6 V), other voltages on request (up to 600V)Typical applications:PCB lines Characteristic valuesSwitch mode technologyDual output, 4-fold output (single output optional) (see below matrix)Linearity inaccuracy Ripple less than Complex waveformsConstant current regulation (voltage regulation on request)SPI interface for control unit pe8005Fast rise and fall times (rectangular wav...
  • Features


Pulse Reverse power supplies, Cabinet models

Cooling: Water cooled


Pulse Reverse power supplies, Cabinet models


Output power: max. 64000 Watts
Effective - and DC-current: max. 4240 A
Pulse current: max. 9600 A
Effective voltage: max. 6 V


Output power:  max. 2 x 16000 Watts (max. 4 x 8000 Watts)

Effective - and DC-current:  max. 2 x 1060 A (max. 4 x 424 A)

Reverse-current: max. 2 x 2400 A (max. 4 x 960 A)

Effective voltage: Standard 2 x 6 V (4 x 6 V), other voltages on request (up to 600V)


Typical applications:

PCB lines 


Characteristic values

Switch mode technology


Dual output, 4-fold output (single output optional) (see below matrix)

Linearity inaccuracy < 1 % (related to nominal DC value)

Ripple less than < 1 % (related to nominal DC value)

Complex waveforms

Constant current regulation (voltage regulation on request)

SPI interface for control unit pe8005

Fast rise and fall times (rectangular waveforms)

Permanent short circuit and open circuit proof

Microprocessor controlled regulation

Mains supply: standard 380 V - 460 V/3~ +/- 10 % / 50-60 Hz Optional: 200 V - 240 V/3~ +/- 10 % / 50-60 Hz

Max. effective output power: see below matrix 


Cooling

Water cooled (designed for the direct installation at the electroplating tank)
Ambient temperature 40°C
Over temperature protected 


Design

Compact stainless steel casing; protection grade IP54 

DC/Pulse connection in back panel (tin copper bus bars) 



Type

pe80CD122 / pe80CD124

pe80CD202 / pe80CD204

pe80CD322 / pe80CD324*

pe80CD402 / pe80CD404*

Forward current

2 x 120 A / 4 x 120 A

2 x 200 A / 4 x 200 A

2 x 320 A / 4 x 320 A

2 x 400 A / 4 x 400 A

Reverse pulse current

2 x 360 A / 4 x 360 A

2 x 600 A / 4 x 600 A

2 x 960 A / 4 x 960 A

2 x 1200 A / 4 x 1200 A

Current ratio IF : IR

free adjustable

Effective current / DC

2 x 159 A / 4 x 159 A

2 x 265 A / 4 x 265 A

2 x 424 A / 4 x 424 A

2 x 530 A / 4 x 530 A

Minimum time reverse-pulse

0,1 msec.

Water cooling


Max. water inlet temperature

23 - 26°C

Max. water outlet temperature

40°C

Water consumption approx.

3 l/min (*3,6 l/min)

Type

pe80CD442

pe80CD482

pe80CD522

pe80CD602

Forward current

2 x 440 A

2 x 480 A

2 x 520 A

2 x 600 A

Reverse pulse current

2 x 1320 A

2 x 1440 A

2 x 1560 A

2 x 1800 A

Current ratio IF : IR

free adjustable

Effective current / DC

2 x 583 A

2 x 636 A

2 x 689 A

2 x 795 A

Minimum time reverse-pulse

0,1 msec.

Water cooling


Max. water inlet temperature

23 - 26°C

Max. water outlet temperature

40°C

Water consumption approx.

3 l/min

3,4 l/min

Type

pe80CD642

pe80CD722

pe80CD762

pe80CD802

Forward current

2 x 640 A

2 x 720 A

2 x 760 A

2 x 800 A

Reverse pulse current

2 x 1920 A

2 x 2160 A

2 x 2280 A

2 x 2400 A

Current ratio IF : IR

free adjustable

Effective current / DC

2 x 848 A

2 x 954 A

2 x 1007 A

2 x 1060 A

Minimum time reverse-pulse

0,1 msec.

Water cooling


Max. water inlet temperature

23 - 26°C

Max. water outlet temperature

40°C

Water consumption approx.

3,7 l/min

4,1 l/min

4,4 l/min

4,6 l/min


Operation / programming
(via external pe8005 control unit)


Large illuminated 5,7“ graphic display
5 x 4 keypad for easy handling and navigation

Clear and user friendly menu navigation via well structured pull down menus

Easy generation of complex waveforms with up to 16 individual steps with 2 individual amplitudes (Ix1 and Ix2 as well as tx1 and tx2), that can be positive or negative

MMC/SD card reader for software update, import / export of device configuration, set values and storing of bus-logging data

RS485 interface (optional: PROFIBUS or TCP/IP) Synchronization function
2 programmable output relays
Ah-totalizer, dosage counter, timer Programmable START ramp

Parameters individually adjustable even during operation


Display

Clear display of actual values

Graphic view of the set value shape, actual values shown in oscilloscope-mode with real time oscilloscope-function

Status, warning and error indication


Resolution

0 up to +/- xx.xA for Ix1 and Ix2; resolution: 100mA
0 up to 9 999.9mSec for tx1 and tx2; resolution: 0,1mSec Cycles (repeatings per step): 1 - 99 

Pulse Reverse power supplies, Cabinet models




Release Time: 2021 - 04 - 01
Pulse Reverse power supplies, Cabinet modelsCooling: Water cooledOutput power: max. 64000 WattsEffective - and DC-current: max. 4240 APulse current: max. 9600 AEffective voltage: max. 6 VOutput power:  max. 2 x 16000 Watts (max. 4 x 8000 Watts)Effective - and DC-current:  max. 2 x 1060 A (max. 4 x 424 A)Reverse-current: max. 2 x 2400 A (max. 4 x 960 A)Effective voltage: Standard 2 x 6 V (4 x 6 V), other voltages on request (up to 600V)Typical applications:PCB lines Characteristic valuesSwitch mode technologyDual output, 4-fold output (single output optional) (see below matrix)Linearity inaccuracy Ripple less than Complex waveformsConstant current regulation (voltage regulation on request)SPI interface for control unit pe8005Fast rise and fall times (rectangular wav...
Release Time: 2016 - 02 - 28
Pulse Reverse power suppliesPulse Reverse power supplies, Bench top modelsCooling: Air cooledOutput power: max. 6360 WattsEffective - and DC-current: max. 318 APulse current: max. 720 AEffective voltage: max. 500 VOutput power:  max. 6360 WattsEffective - and DC-current:  max. 318 AReverse-current: max. 720 AEffective voltage: max. 500 VTypical applications:PCB lines Pulse plating Reel-to-reel plating Characteristic valuesSwitch mode technologySingle or Dual output availableLinearity inaccuracy Ripple less than Complex waveformsConstant current regulation (voltage regulation on request)SPI interface for control unit pe8005Fast rise and fall times (rectangular waveforms)Permanent short circuit and open circuit proofMicroprocessor controlled regulationMains supp...
Release Time: 2017 - 01 - 01
Pulse Reverse power RectifiersPOWER PULSE, PULS-REVERSE-STROMQUELLEPulse Reverse power supplies, Bench top modelsCooling: Air cooledOutput power: max. 200 WattsEffective - and DC-current: max. 10 APulse current: max. 50 AEffective voltage: max. 20 VOutput power: max. 200 WattsEffective - and DC-current: max. 10 APulse current: max. 50 AEffective voltage: max. 20 VTypical applications:Pulse plating Laboratory plating lines Characteristic valuesLinear controlledLinearity inaccuracy Ripple less than Complex waveformsConstant current regulation (standard)RS485-interface (optional: PROFIBUS or TCP/IP)MMC/SD card reader for software update, import / export of deviceconfiguration, set values and storing of bus-logging dataFast rise and fall times (rectangular waveforms)Permanent sh...
Hot Products / Hot Products More
2021 - 05 - 12
Anode Baskets,Bags & HooksAnode Baskets Titanium anode baskets or anode cages are available in a variety of shapes, sizes and materials. They are designed to hold the anodes, which provide a source of metallic ions to be plate...
2021 - 04 - 01
Pulse Reverse power supplies, Cabinet modelsCooling: Water cooledOutput power: max. 64000 WattsEffective - and DC-current: max. 4240 APulse current: max. 9600 AEffective voltage: max. 6 VOutput power:  max. 2 x 16000 Watts (max. 4 x 8000 Watts)Effective - and DC-current:  max. 2 x 1060 A (max. 4 x 424 A)Reverse-current: max. 2 x 2400 A (max. 4 x 960 A)Effective voltage: Standar...
2021 - 03 - 16
PVDF/PFA/PTFE Heat ExchangersTeflon(Fluorpolymer) Heating and cooling coilsExchange areaSq.FtConnectionsInchLengthIn./mmWidthIn./mmThicknessIn./mmModel No.5.53/4 FNPT11.5(292)11.5(292)2(51)XC-12-12113/4 FNPT15.5(394)15.5(394)2(51)XC-16-1616.53/4 FNPT17.5(445)17.5(445)2.36(60)XC-18-18223/4 FNPT19.7(500)15.7(400)2.36(60)XC-20-1627.53/4 FNPT19.7(500)19.7(500)2.36(60)XC-20-20333/4&...
Service Hotline
020-31056110
客户端下载
Client Downloads
Copyright ©2005 - 2013 Guangzhou Precise Heater Co.,LTD
犀牛云提供企业云服务