Products Products
  / Products
Release Time: 2021 - 05 - 12
Anode Baskets,Bags & HooksAnode Baskets Titanium anode baskets or anode cages are available in a variety of shapes, sizes and materials. They are designed to hold the anodes, which provide a source of metallic ions to be plated, and carry the electric current that drives the electroplating process.PreciseHeater is dedicated to being the premiere supplier of corrosion resistant anode baskets to the Metal Finishing, Plating and Anodizing Industries.Anode baskets are built to the highest standards in the industry and are backed by a five-year warranty on workmanship. If st...
Release Time: 2021 - 04 - 01
Pulse Reverse power supplies, Cabinet modelsCooling: Water cooledOutput power: max. 64000 WattsEffective - and DC-current: max. 4240 APulse current: max. 9600 AEffective voltage: max. 6 VOutput power:  max. 2 x 16000 Watts (max. 4 x 8000 Watts)Effective - and DC-current:  max. 2 x 1060 A (max. 4 x 424 A)Reverse-current: max. 2 x 2400 A (max. 4 x 960 A)Effective voltage: Standard 2 x 6 V (4 x 6 V), other voltages on request (up to 600V)Typical applications:PCB lines Characteristic valuesSwitch mode technologyDual output, 4-fold output (single output optional) (see below matrix)Linearity inaccuracy Ripple less than Complex waveformsConstant current regulation (voltage regulation on request)SPI interface for control unit pe8005Fast rise and fall times (rectangular wav...
Release Time: 2021 - 03 - 16
PVDF/PFA/PTFE Heat ExchangersTeflon(Fluorpolymer) Heating and cooling coilsExchange areaSq.FtConnectionsInchLengthIn./mmWidthIn./mmThicknessIn./mmModel No.5.53/4 FNPT11.5(292)11.5(292)2(51)XC-12-12113/4 FNPT15.5(394)15.5(394)2(51)XC-16-1616.53/4 FNPT17.5(445)17.5(445)2.36(60)XC-18-18223/4 FNPT19.7(500)15.7(400)2.36(60)XC-20-1627.53/4 FNPT19.7(500)19.7(500)2.36(60)XC-20-20333/4 FNPT23.5(597)23.5(597)2.36(60)XC-24-2438.53/4 FNPT27.5(700)23.5(597)2.36(60)XC-28-24443/4 FNPT27.5(700)27.5(700)2.76(70)XC-28-2849.53/4 FNPT31.5(800)31.5(800)2.76(70)XC-32-32551 FNPT33.9(860)33.9(860)2.76(70)XC-34-3460.51 FNPT35.5(900)31.5(800)2.76(70)XC-36-32661 FNPT35.5(900)33.9(860)2.76(70)XC-36-3471.51 FNPT35.5(900)35.5(900)2.76(70)XC-36-36771 FNPT39.5(1000)33.9(860)3.15(80...
Release Time: 2016 - 07 - 27
Ruthenium Iridium Titanium AnodesBecause of a very flexible production facility, we are able to manufacture anodes of all types: sheet, plate, mesh, wire, rod, tubular or combinations and/or assemblies of these materials. Their size and number vary from several cm2 to 2 m2 and from 1 to 10,000 pieces. The process in which the anodes are used determines size, shape and coating specification of an anode.Important parameters determining the anode design are:◆ The electrochemical cell or installation wherein the anodes are used◆ The process conditions, such as electrolyte composition, temperature, current density, design life, etc.◆ Mechanical load of the anode◆ Capacity of electrical conductivity of the base material.All anodes are produced according to customer specifications. When these spe...
Release Time: 2016 - 07 - 21
Inline Fluoropolymer Chemical Heat Exchangers:Fluoropolymer Inline Heat ExchangersExchange Area(Sq.Ft)LengthIn(mm)DIAIn(mm)PP ShellPVDF Shell6.515.7(400)10(255)XCH6.5-***XPH6.5-***1315.7(400)12(305)XCH13-***XPH13-***2020(500)14(355)XCH20-***XPH20-***3020(500)14(355)XCH30-***XPH30-***4024(600)14(355)XCH40-***XPH40-***5024(600)16(405)XCH50-***XPH50-***6027.5(700)16(405)XCH60-***XPH60-***7027.5(700)16(405)XCH70-***XPH70-***8031.4(800)16(405)XCH80-***XPH80-***9031.4(800)18(460)XCH90-***XPH90-***10031.4(900)18(460)XCH100-***XPH100-***11031.4(900)20(510)XCH110-***XPH110-***12039(1000)20(510)XCH120-***XPH120-***13039(1000)20(510)XCH130-***XPH130-***14043(1100)22(560)XCH140-***XPH140-***15043(1100)22(560)XCH150-***XPH150-***16047(1200)22(560)XCH160-***XPH160-***  lnine chemical heat exch...
Release Time: 2016 - 07 - 21
Metal Heating and Cooling Grid CoilsDesigned for the high demands of corrosive chemical heatingor cooling DOUBLE C STYLE GRID COILS DCGExchange Area Squre Ft12-1/2” WIDTH Tubes Depth(In./mm)     Length(In./mm)    Model number6.582612.5/31814/35526DCG-148.82612.5/31818/45726DCG-18122612.5/31824/60926DCG-2415.62612.5/31830/76226DCG-30192612.5/31836/91426DCG-3625.82612.5/31848/1,21926DCG-48292612.5/31854/1,37126DCG-5434.92612.5/31864/1,62526DCG-6418-1/2” WIDTH Tubes  Depth(In./mm)   Length(In./mm)      Model number133818.5/47018/45738DCG-18183818.5/47024/60924DCG-24233818.5/47030/76224DCG-3027.93818.5/47036/91424DCG-36353818.5/47048/1,21924DCG-4842.93818.5/47054/1,37124DCG-54513818.5/47064/1,62524DCG-6459.53818.5/...
Release Time: 2016 - 07 - 21
SmartOne PTC Max Single Over the Side Heater :SmartOne heaters' elements are PTC positive temperature coefficient semiconductors – making the heaters self-limiting. That is, they reach a set maximum sheath temperature (which is below the ignition point of most combustible materials), meaning they are especially safe for process applications. WATTSVOLTSHot ZoneMM/IN.Overall MM/IN.304SS316SSTitaniumShip Wt.Lbs./(Kg)1000120240180(7)280(11)S1SP1111S1SP1211S1TP1111S1TP12117(3.5)2000240480330(13)430(17)S1SP2117S1SP2217S1TP2117S1TP221710(4.5)3000240480460(18)585(23)S1SP3223S1SP3423S1TP3223S1TP342311(5)4000240480610(24)735(29)S1SP4229S1SP4429S1TP4229S1TP442913(6)5000240480760(30)890(35)S1SP5235S1SP5435S1TP5235S1TP543515(7)6000240480890(35)1040(41)S1SP6241S1SP6441S1TP6241S1TP644117(8)...
Release Time: 2016 - 07 - 19
HX Style Spiral Over the side Teflon PTFE HEATERS:Specify thermal overload protection desired. Guards are recommended on over the side heaters and required on L-Shaped heaters. Standard guard is polypropylene. Fluoropolymer (PTFE) guards recommended for chromic acid and solutions exceeding 180º F (82ºC).GUARDS SOLD SEPARATELY WATTSVOLTSHot zonemm/inOverallmm/inMax coldzoneModel No.Ship WT.Lbs./Kg500120-240125(5)280(11)41(1040)HXP.5111HXP.5211   6  (2.5)1000120-240180(7)280(11)41(1040)HXP1111HXP1211   7  (3.5)2000120-240305(12)430(17)41(1040))HXP2117HXP2217HXP2417   8   (4)3000120-600405(16)585(23)41(1040)HXP3223HXP3423   13   (6)4000120-600510(20)735(29)41(1040)HXP42...
Release Time: 2016 - 07 - 13
3’’-5’’-6’’ Flange Heaters -Tubular Flanged Immersion HeatersTubular Heater Industrial Heating Heater: 3' 150 lbs. Stainless Steel Flange (3 Elements) Heater:WATTSVOLTSLengthMM./INModel NumberShip Wt.LBS./(Kg)3000240480230(9)3FLSP32093FLSP3409  14 (6.5)4500240480330(13)3FLSP4.52133FLSP4.5413  15  (7)6000240480485(19)3FLSP62193FLSP6419   16  (7.5)9000240480660(26)3FLSP92263FLSP9446  17  (8)12000240480840(33)3FLSP122333FLSP12433  18  (8.5)150002404801015(41)3FLSP152413FLSP15441 20 (9)180002404801245(49)3FLSP182493FLSP18449  21  (10)   5' 150 lbs. Stainless Steel Flange (6 Elements) Heater: WATTSVOLTSLengthMM./INModel NumberShi...
Products Product Details

Temperature Protectors

Spec:
Scope:
Availability: 2021 - 05 - 12
Describe:
Explain:
Temperature Protectors1, 2, and 3 Series ProtectorsThermal overload protectionThe Protector 1 overtemperature control system utilizes a heat sensitive fuse to detect overheat conditions. The protector, placed inside a thermowell, positioned in contact with the heater sheath, will cut power to the heater in the event of low liquid The Protector 2 and Protector 3 systems provide the same reliable overtemperature protection as Protector 1 However, the control systems feature a heat sensing thermostat. If the liquid level drops and the heater reaches a preset overheat heater can quickly be made operational by pushing the reset button on the control to restore power. Protector 3 is designed for flexible lead or high temperature fluoropolymer (PTFE) heater applications only.
  • Features

Temperature Protectors

Temperature Protectors

1, 2, and 3 Series Protectors

Thermal overload protection


The Protector 1 overtemperature control system utilizes a heat sensitive fuse to detect overheat conditions. The protector, placed inside a thermowell, positioned in contact with the heater sheath, will cut power to the heater in the event of low liquid The Protector 2 and Protector 3 systems provide the same reliable overtemperature protection as Protector 1 

However, the control systems feature a heat sensing thermostat. If the liquid level drops and the heater reaches a preset overheat heater can quickly be made operational by pushing the reset button on the control to restore power. Protector 3 is designed for flexible lead or high temperature fluoropolymer (PTFE) heater applications only.


Release Time: 2008 - 11 - 05
Digital Temperature Controllers unit with D1/16 Din Digital Thermostats Single Setpoint sensorSimple to Set and Operate 1/16 DIN Size ControllersThis multi-range 1/16 DIN controller with alarm function offers field-selectable PID control or ON/OFF control. The large, single display shows process value, direction of deviation from set point, output and alarm status.Easy setting using internal DIP and rotary switchesON/OFF or PID control (with on-demand auto-tuning) selectableClearly visible digital display with character height of 13.5 mmDeviation indicator makes monitoring more effectiveMultiple temperature sensor input (thermocouple/platinum resistance thermometer) models stocked; thermocouple input only and platinum RTD input only models availableModels with two alarms are ideal for temp...
Release Time: 2001 - 04 - 16
Heating Temperature Controller SystemThe cables and sensors of theheating systems are inserted intothe control cabinet via cable glandssituated at its base and are tightlywired at the clamping strips. Atemperature probe with a Pt 100sensor element must be connectedfor temperature control; a MTSufloating switch or alternatively aconductive NS 2 level rod probemust be connected for fluid levelmeasurement.A floating switch with an integratedtemperature probe (MTSt) or a level rod probe with an integrated temperature probe (NT 2) can ofcourse be connected in place of indi-vidual sensors. The connection of aseparate temperature probe is in thiscase not necessary.Unused cable seals are closed withblind plugs.When connecting single-phaseimmersion heaters use safety im-mersion heaters wi...
Release Time: 2021 - 05 - 17
CE Conductive Liquid Level ControlLevel probes & Float Switches(PP/PVDF)Provides automated control and consistent liquid levels in most conductive aqueous processes, waste treatment tanks and when leak detection is required.Adds protection against damage and tank fires associated with low-level conditions.Probe enclosure: vapor tight, flame retardant, polyproylene head with 10-foot (3m) flexible cord and quick connect plug for easy connection to remote circuitry.Two probe units (LP-2): for single point control. Multi probe units (LP-3): for two-point control and refill/pump down applications. 4,5 or 6-probe devices for multiple level control applications, LCBA5 - Level switch electronics (only) mounted in plastic enclosure. 2-probe unitsElectronic Assembly field selectable voltage...
Release Time: 2016 - 07 - 21
Temperature Probes with PT100 sensorPT100 RTD Sensor - Pt100 temperature sensor - RTD - PT100 - Sensor MeasurementPRODUCT DESCRIPTIONProvides automated control and consistent liquid levels for most aqueous processes and waste treatment tanks, or when leak detection is required.FEATURESHelps protect against fires and tank damage associated with low-level conditions.Dual probe units: for single point control. Multi probe units: for two-point control and refill/pump down applications.Fluoropolymer (PTFE) covered: 316 stainless steel, titanium, Hastelloy C® and graphite tipped Hastelloy probe materials.Control enclosure: gasketed UL Type 1, IP21 (indoor) polypropylene box with stainless steel hardware.Probe enclosure: vapor resistant polypropylene head with 10-foot (3m) flexible lead and ...
Release Time: 2021 - 05 - 17
Single phase Control PanelAll plastic design for a perfect usein surface treatment plants andchemicals storage areas DescriptionPreciseHeater 2M07-3 Control Panel, Single phaseCompact, simple to use, ready to plugDigital displayIP55A simple solution for regulation: this PID digital display control box (with input PT100 3 wires) controls up to 7 kW 230V single-phase, 50/60 HzPreciseHeater 2M07-3On-off switch with indicator light on the front.Five cable-glands for: box supply, immersion heater, PT100 probe, level security and thermal security.Compact and ready to plug the galvabox range is simple to use.Digital display of set point temperature as well as temperature measured for an efficient control.The control box includes a plug-in terminal which centralizes plugs-in for supply, heati...
Release Time: 2016 - 07 - 21
Rod Thermostats - Heating Rod ThermostatsPrecise Heater Rod Thermostats are suitable for use with Single Phase to control heating in electroplating baths.They are equipped with a 1.6 metre supply cord and standard red cap terminal casing.The probe diameter and materials are as follows:-Stainless Steel: 11 mmPolypropylene:16 mmPTFE:12 mmThe temperature control probe is suitable for automatic control of a pre-set value in the process media and are suitable for heaters up to 2.3 kw single phase. For higher loads, or three phase heaters an additional contactor should be used.The probes construction makes it ideally suited for etch, pickle and plating solutions. Its robust construction and chemical resistance ensures a long service life.Operating Temperature Range:0 to 120°CInsul...
Release Time: 2006 - 04 - 28
Temperature Control PanelsTemperature Control panels are used to maintain the stability and the heat transfer efficiency of the heating system to prevent issues such as overheating and chemical disintegrations of a fluid. In order to provide the precise safety mechanism of the heating system.Temperature Control panels can also be entirely customized to meet most of the requirements of the target application. There are a variety of terminal boxes available to select depending on the protection for: moisture, explosion, waterproof, and dustproof. A NEMA 1 standard terminal box is normally suitable for non-hazardous area operation. NEMA 4 terminal boxes (weather resistant enclosure) are commonly used for outdoor operation, which requires protection against moisture and humidity. Dig...
Release Time: 2021 - 04 - 16
Electronic Temperature ControllerRelay/ControlSingle Set-Point, 30 ampsProvides precise control for consistent plating and etch rates in most aqueous processes. Large (.56” high), easy to read LED display. Fluoropolymer (FEP) covered 10-foot (3m), 1000-ohm thermistor sensor included standard with the control. Vapor tight, IP21, front panel protection, plastic enclosure with sealed tactile switches. 30 amp switching capacity for either 120 or 240 volts. Single phase. Adjustable temperature range from -58°F (-50°C) to 302°F (150°C). ApplicationsSurface FinishingGeneral Metal Finishing (GMF)AnodizingWaste Water TreatmentAquaculture
Release Time: 2021 - 04 - 15
Temperature probe with Temperature PT100 SensorsParticularly in surface treatment, theprecise measurement and control of temperatures is of decisive im-portance for the subsequent qualityof the treated items. To keep thetemperature of the liquid in storagetanks within the desired range, also prevents negative effects onthe process liquids, such as freez-ing, crystallisation and excessiveviscosity.The following functions need to beimplemented:• Control of the temperature inorder to automate process steps(such as keeping the desiredprocess temperature)• Monitoring of the temperature in order to avoid possible damageto the process, the process liquid(e.g. damage by excessive tem-peratures) and the tank (e.g. thermal damage)With the aid of temperature sen-sors and suitable ...
Release Time: 2006 - 03 - 29
Detecting liquid levels with conductive Level Rod-ProbesLiquid levels in process and stor-age tanks need to be measuredand monitored, since unwantedvariations in these levels (due toevaporation or removal of the pro-cess liquids) must be corrected. Inthis respect, there are two differentgeneral tasks:• control of the level in order topermit automatic executionof process operations (such asdosing of liquids)Possible deposits of encrustationbetween the tips of the probe canbe avoided by ensuring that thedifference between the probe-rodlengths is at least 60 mm.The levels of non-conductive orpoorly conducting liquids, in whichlevel rod-probes cannot be used,can be controlled and monitored byour float switches.The level rod-probes are available inmany different versions:• with two to five rods...
Release Time: 2008 - 05 - 28
Three phase Control PanelAll plastic design for a perfect usein surface treatment plants andchemicals storage areas DescriptionGalvabox 5T15-3 Control Panel, Three phasesCompact, simple to use, ready to plugDigital displayIP55A simple solution for regulation: this PID digital display control box (with input PT100 3 wires) controls up to 15 kW 400V three-phases, 50/60 Hz.Galvabox 5T15-3On-off switch with indicator light on the front.Five cable-glands for: box supply, immersion heater, PT100 probe, level security and thermal security.Accessories and OptionsPT100 3 WIRES PROBESCompact and ready to plug the galvabox range is simple to use.Digital display of set point temperature as well as temperature measured for an efficient control.The control box includes a plug-in terminal which cent...
Release Time: 2006 - 04 - 15
Conductive Level ProbesLiquid levels in process and stor-age tanks need to be measuredand monitored, since unwantedvariations in these levels (due toevaporation or removal of the pro-cess liquids) must be corrected. Inthis respect, there are two differentgeneral tasks:• control of the level in order topermit automatic executionof process operations (such asdosing of liquids)Possible deposits of encrustationbetween the tips of the probe canbe avoided by ensuring that thedifference between the probe-rodlengths is at least 60 mm.The levels of non-conductive orpoorly conducting liquids, in whichlevel rod-probes cannot be used,can be controlled and monitored byour float switches.The level rod-probes are available inmany different versions:• with two to five rods for detec-tion of one to four di...
Release Time: 2016 - 07 - 21
Temperature Controls (Heating Control System)Temperature ControllersCombination ControlDual Set-Point, 20 - 125 ampsProvides precise digital control for consistent plating and etch rates in most aqueous processes. Combination control features .3 inch (7.6mm), dual LED displays. Fluoropolymer (FEP) covered 10-foot 3m), 1000-ohm platinum RTD sensor included standard with the control. NEMA 1, IP21, flame retardant and gasketed plastic enclosure with stainless steel hardware. Dual setpoint with heating and cooling up to 30 amps. 120-240 volts. Single phase. Adjustable temperature range from -328°F (-200°C) to 4208°F (2320°C).Any electrically heated container must be equipped with a thermostat and a level monitoring system. It is, however, often not possible to integrat...
Release Time: 1999 - 04 - 01
Temperature Protectors1, 2, and 3 Series ProtectorsThermal overload protectionThe Protector 1 overtemperature control system utilizes a heat sensitive fuse to detect overheat conditions. The protector, placed inside a thermowell, positioned in contact with the heater sheath, will cut power to the heater in the event of low liquid The Protector 2 and Protector 3 systems provide the same reliable overtemperature protection as Protector 1 However, the control systems feature a heat sensing thermostat. If the liquid level drops and the heater reaches a preset overheat heater can quickly be made operational by pushing the reset button on the control to restore power. Protector 3 is designed for flexible lead or high temperature fluoropolymer (PTFE) heater applications only.
Hot Products / Hot Products More
2021 - 05 - 12
Anode Baskets,Bags & HooksAnode Baskets Titanium anode baskets or anode cages are available in a variety of shapes, sizes and materials. They are designed to hold the anodes, which provide a source of metallic ions to be plate...
2021 - 04 - 01
Pulse Reverse power supplies, Cabinet modelsCooling: Water cooledOutput power: max. 64000 WattsEffective - and DC-current: max. 4240 APulse current: max. 9600 AEffective voltage: max. 6 VOutput power:  max. 2 x 16000 Watts (max. 4 x 8000 Watts)Effective - and DC-current:  max. 2 x 1060 A (max. 4 x 424 A)Reverse-current: max. 2 x 2400 A (max. 4 x 960 A)Effective voltage: Standar...
2021 - 03 - 16
PVDF/PFA/PTFE Heat ExchangersTeflon(Fluorpolymer) Heating and cooling coilsExchange areaSq.FtConnectionsInchLengthIn./mmWidthIn./mmThicknessIn./mmModel No.5.53/4 FNPT11.5(292)11.5(292)2(51)XC-12-12113/4 FNPT15.5(394)15.5(394)2(51)XC-16-1616.53/4 FNPT17.5(445)17.5(445)2.36(60)XC-18-18223/4 FNPT19.7(500)15.7(400)2.36(60)XC-20-1627.53/4 FNPT19.7(500)19.7(500)2.36(60)XC-20-20333/4&...
Service Hotline
020-31056110
客户端下载
Client Downloads
Copyright ©2005 - 2013 Guangzhou Precise Heater Co.,LTD
犀牛云提供企业云服务