新闻资讯 News
News 新闻资讯
Taipei,Taiwan,ChinaOct 26-28,2016
发布时间: 2016 - 07 - 13
浏览次数:143
Hannover, GermanyApr 25-29, 2016
发布时间: 2016 - 07 - 13
浏览次数:125
Service Hotline
020-31056110
新品来袭
 
 
推荐产品 / Products
发布时间: 2016 - 07 - 21
Metal Heating and Cooling Grid CoilsDesigned for the high demands of corrosive chemical heatingor cooling For use in most alkaline oracid solutionsVertical or horizontalconfigurationsEvery inch of coil surfaceis active exchange area2-inch thick, low profiledesign 316 stainless steel,Zirconium, Hastelloy Cand Titanium4.6 square foot to 89.9square foot of exchangearea100 PSI working pressure(steam or water) Features & Values   Wide variety of materials available for use in heatingor cooling applications for alkaline or acid solutionsand rinse tanks. Check solution guide or consult withyour chemical supplier for proper sheath material.   Heavy wall, 20 gauge metal tubing available in steel,316 stainless steel and titanium.  1” diamete...
发布时间: 2016 - 07 - 21
SmartOne PTC Max Single Over the Side Heater : SmartOne heaters' elements are PTC positive temperature coefficient semiconductors – making the heaters self-limiting. That is, they reach a set maximum sheath temperature (which is below the ignition point of most combustible materials), meaning they are especially safe for process applications. WATTSVOLTSHot ZoneMM/IN.Overall MM/IN.304SS316SSTitaniumShip Wt.Lbs./(Kg)1000120240180(7)280(11)S1SP1111S1SP1211S1TP1111S1TP12117(3.5)2000240480330(13)430(17)S1SP2117S1SP2217S1TP2117S1TP221710(4.5)3000240480460(18)585(23)S1SP3223S1SP3423S1TP3223S1TP342311(5)4000240480610(24)735(29)S1SP4229S1SP4429S1TP4229S1TP442913(6)5000240480760(30)890(35)S1SP5235S1SP5435S1TP5235S1TP543515(7)6000240480890(35)1040(41)S1SP6241S1SP6441S1TP6241S1TP644...
发布时间: 2016 - 07 - 19
Vertical Spiral Over the side Teflon PTFE HEATERS: WATTSVOLTSHot zonemm/inOverallmm/inMax coldzoneModel No.Ship WT.Lbs./Kg500120-240125(5)280(11)41(1040)HXP.5111HXP.5211   6  (2.5)1000120-240180(7)280(11)41(1040)HXP1111HXP1211   7  (3.5)2000120-240305(12)430(17)41(1040))HXP2117HXP2217HXP2417   8   (4)3000120-600405(16)585(23)41(1040)HXP3223HXP3423   13   (6)4000120-600510(20)735(29)41(1040)HXP4229HXP4429   15   (7)5000120-600635(25)890(35)36(915)HXP5235HXP5435   18   (8)6000120-600735(29)1015(40)30(760)HXP6240HXP6440   21   (10)8000120-600940(37)1195(47)41(1040)2HXP82472HXP8447  ...
发布时间: 2016 - 07 - 13
Single SPIRAL L-SHAPED Teflon PTFE HEATERS:Low Profile Bottom HeaterWATTSVOLTSHot zonemm/inRisermm/inMax coldzoneModel No.Ship WT.Lbs./Kg500120240155(6)305(12)41(1040)HXLP.5106HXLP.5206   6  (2.5)1000120240205(8)305(12)41(1040)HXLP1108HXLP1208   7  (3.5)2000120240480430(17)460(18)40(1015)HXLP2112HXLP2212HXLP2412   8   (4)3000240480430(17)460(18)40(1015)HXLP3217HXLP3417   13   (6)4000240480510(20)460(18)40(1015)HXLP4220HXLP4420   15   (7)5000240480610(24)460(18)36(915)HXLP5224HXLP5424   18   (8)6000240480735(29)460(18)30(760)HXLP6229HXLP6429   21   (10)8000240480940(37)460(18)40(1015)2HXLP82372...
发布时间: 2016 - 03 - 27
POWER STATION DC Cabinet RectifiersDC POWER SUPPLY Output power:max. 110kWDC current:  max. 5000A (at 22V)DC voltage:  max. 1000V (at 100A) Typical applications:Chrome platingAnodizing/Aluminium colouring Barrel platingRack plating Water cooled DC power supply in switch mode technology,designed for the direct installation at the electroplating tank withminimal space requirement. Variable output rangethe output range can be individually multiplied Characteristic valuesLinearity inaccuracy:- for amperage - for voltage Ripple less than Efficiency typical 85 % Powerfactor cos φ 0,95Constant current and voltage controlSoft start functionOver temperature protection Pulse operation optional Mains supply: standard 3 x 400 V +/- 10 % / 50-60 H...
发布时间: 2001 - 04 - 16
Heating Temperature Controller SystemThe cables and sensors of theheating systems are inserted intothe control cabinet via cable glandssituated at its base and are tightlywired at the clamping strips. Atemperature probe with a Pt 100sensor element must be connectedfor temperature control; a MTSufloating switch or alternatively aconductive NS 2 level rod probemust be connected for fluid levelmeasurement.A floating switch with an integratedtemperature probe (MTSt) or a level rod probe with an integrated temperature probe (NT 2) can ofcourse be connected in place of indi-vidual sensors. The connection of aseparate temperature probe is in thiscase not necessary.Unused cable seals are closed withblind plugs.When connecting single-phaseimmersion heaters use safety im-mersion heaters wi...
Service Hotline
020-31056110
客户端下载
Client Downloads
Copyright ©2005 - 2013 Guangzhou Precise Heater Co.,LTD
犀牛云提供企业云服务